Magnetic Stirred Reactor: Installation, Operation, and Maintenance of the Magnetic Stirred Reactor Controller
The editor of Weihai Self-Control Reactor Co., Ltd. would like to remind you of the following points regarding magnetic stirrer reactors: (1) Be sure to understand the material of the magnetic stirrer reactor you are using; the medium should fall within the corrosion-resistant range of that material. (2) Regularly inspect and check the pressure components and calibrate the instruments. (3) Materials that are toxic, flammable, or explosive and pose a hazard to human health should be discharged through the safety valve. (4) If the needle valve malfunctions, it can be disassembled and cleaned; the valve needle can be replaced, and a hydraulic test should be conducted before installation and use. (5) The magnetic stirrer reactor and the instrument box must be properly grounded.
Release time:
2020-04-24 12:02
Source:
According to Magnetic Stirred Reactor The label on the rear panel connects the power cable. The wiring from the controller to the magnetic reactor consists of: a two-core cable for the electric furnace, a rubber cable, a three-core cable for the motor, and a dedicated temperature-measuring cable. Connect the ground wire of the control instrument to the ground wire of the reactor tube, and then connect this combined ground wire to the power supply’s ground wire, ensuring that the grounding resistance of both the magnetic reactor and the controller is less than 4 ohms.

1) Ensure stable installation with a cabinet tilt no greater than 5°C to guarantee reliable operation of the measuring instruments.
2) Turn on the power switch; the power indicator light will illuminate, indicating that the power is on.
3) Magnetic Stirred Reactor Operation of electric heating: First, adjust the setpoint on the thermostat, turn on the heating switch to energize the heating circuit, and then appropriately adjust the heating potentiometer. This allows for stepless adjustment of voltage and achieves the desired constant temperature, while also ensuring that the heating rate meets the required specifications.
4) Magnetic Stirred Reactor Maintenance and upkeep of the controller: Before normal operation begins, it is essential to check for any abnormalities. During operation, opening the cabinet is strictly prohibited. Measurement instruments should be calibrated regularly to ensure accuracy. The equipment’s operating environment must comply with safety and technical requirements.
Weihai Self-Control Reactor Co., Ltd. Here are a few additional points that the editor would like to remind you about regarding magnetic stirring reactors:
1) You need to know what is being used. Magnetic Stirred Reactor The medium should be within the corrosion-resistant range of the material.
2) Regularly inspect and check the pressure components and calibrate the instruments.
3) Magnetic Stirred Reactor Materials that are toxic or flammable and explosive and can react with the human body should be discharged through the safety valve.
4) If the needle valve malfunctions, it can be disassembled and cleaned. The valve needle can be replaced, and a hydraulic test should be conducted before installation and use.
5) Magnetic Stirred Reactor The instrument case must be grounded.
Reaction vessels, magnetic stirrer reaction vessels, titanium reaction vessels, hydrogenation reaction vessels, manufacturers of reaction vessels