Installation and Use of Autoclaves
The autoclave should be placed in a high-pressure operating room that meets explosion-proof requirements. If multiple autoclaves are installed, they should be arranged separately and physically separated by an appropriate barrier. Each operating room should have direct access to the outdoors or to an exit corridor, and the autoclave must be reliably grounded.
Release time:
2020-03-25 12:34
Source:

Autoclave It should be placed in a high-pressure operating room that meets explosion-proof requirements, especially if multiple units are equipped. Autoclave They should be stored separately. A feasible barrier should be provided between the two. Each operating room should have direct access to the outdoors or to a passageway exit. Autoclave It should be reliably grounded.
When installing the lid, first place the sealing ring, then press the kettle lid into its fixed position, and carefully set it onto the kettle body. The sealing ring between the pure copper and the kettle body and lid features a conical surface contact for sealing. By tightening the main bolt, the components are pressed tightly against each other to achieve a secure seal. The sealing surfaces must be given special protection. When tightening the main bolt, do not exceed the specified tightening torque to prevent crushing or premature wear of the sealing surfaces. Once the sealing surfaces are damaged, they need to be properly treated and repaired to restore their excellent sealing performance. When tightening the bolts, always follow a diagonal, symmetrical, and gradual approach, applying even pressure throughout the process. Do not allow the lid to tilt to one side in order to ensure a good seal. All threaded connections must be lubricated with oil or an oil-based graphite compound during assembly.
Autoclave For heating and pressure sealing tests, the test medium can be either air or nitrogen; however, it is best to use an inert gas. The use of oxygen or other flammable and explosive gases is strictly prohibited. Temperature and pressure increases must be carried out slowly. The heating rate should not exceed 80 degrees Celsius per hour. During the pressure test, connect the pipe to... Autoclave The inlet valve is connected to the compressor (or high-pressure pump). The pressure increase must be carried out in stages, with intervals of 20% of the working pressure. Each stage should be held for 5 minutes, and when reaching the test pressure, the holding time should be extended to 30 minutes while checking for leaks. The test pressure should be set at 100–105% of the working pressure. If any leaks are detected, first reduce the pressure and then carefully tighten the nuts and fittings as appropriate. It is strictly forbidden to tighten nuts and fittings under high pressure.
Autoclave Precautions for Heating and Cooling:
Prohibit rapid cooling and heating. Autoclave This is to prevent the kettle from cracking due to excessive temperature. After the operation is complete, you can cool it down either by passing water through it (exothermic reaction) or by allowing it to air-cool. The needle-valve system features a sealed pipeline; simply turn the valve needle gently and press firmly against the lid to achieve a good seal. Be careful not to apply excessive force, as this could damage the sealing surface. Once the reaction is complete, first allow the temperature to cool down, then release the high-pressure gas from the reactor to reduce the pressure back to atmospheric level, and finally loosen the bolts symmetrically and evenly. When removing the lid, pay special attention to protecting the sealing surface. After each operation, be sure to remove any residual materials from both the kettle body and the kettle lid. Autoclave All sealed surfaces on the unit should be cleaned regularly and kept dry. The use of hard or abrasive soft materials for cleaning is strictly prohibited. The agitator should be removed for cleaning.