Replacement Standards for Pressure Gauges Used in High-Pressure Reactors

The pressure gauges used on high-pressure reactors must be replaced under the following circumstances: 1. For pressure gauges with limiting pins on high-pressure reactors, if the pointer fails to return to the limiting pin position when there is no pressure, or for pressure gauges without limiting pins, if the distance between the pointer and zero exceeds the allowable error of the gauge when there is no pressure. 2. If the glass cover of the dial is broken or the scale markings on the dial are blurred and unclear. 3. If the seal is damaged or the calibration validity period has expired. 4. If there is leakage from the spring tube inside the pressure gauge used on the high-pressure reactor, or if the gauge’s pointer becomes loose. 5. If the pointer is broken or the casing is severely corroded. 6. Any other defects that affect the accurate indication of the pressure gauge.




Standard, pressure gauge, pointer, high pressure, reactor, limit, exceed, dial, pressure, indication